We already got rid of our traditional water heater and were really wanting to have this set up and ready to go by this evening. See price: https://amzn.to/2RzgW0O Eccotemp i12-LP water heater 4 GPM Black 2020 2021. 45HI-LP E1 Code: Troubleshooting Steps Tech Support R September 18, 2017 12:36 UNFOLLOW John Smith, Sept 3, 4:57pm Hi! Ignition system failure. This should match the type of gas that is being supplied. Please note we have received your request and will take all steps necessary to resolve your issue. This is great for energy efficiency. That’s great. The Eccotemp i12-NG is perfect for … The Eccotemp i12-LP is a Liquid Propane-powered, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. 1-866-356-1992 E1 could also be the Flow meter sensor and/or screen filter. 1-866-356-1992 We are happy to help! Maximum Inlet Gas Pressure: Frequency: 60 Hz. Can you hear the water heater trying to ignite? I’ve checked all the steps you listed above, but I’m still getting the E1 code. Manuel du chauffe-eau pour toute la maison Eccotemp 45H / HI LP / NG * Français; Manual del calentador de agua sin tanque para toda la casa Eccotemp 45H / HI LP / … Thank you so much. The Eccotemp i12-LP has a new revolutionary design, making it unlike any other tankless water heater on the market today. Everything relates to gas when getting an E1 code. No worries! Our goal is to provide you with the best customer service possible. Eccotemp Systems, LLC 315-A Industrial Road Summerville, SC 29483 866-356-1992. That worked! E1. The E1/E2 error code is caused by the flame circuit not detecting flame at the burner. Can you please answer the following questions for me? Hard copy product installation manual for the i12 Gas Tankless Water Heater. Contact a gas company to have your gas lines inspected and gas pressure measured. Second, confirm that the gas valve on your supply line is completely open and that there are no blockages or obstructions in the gas line. Find helpful customer reviews and review ratings for Eccotemp i12-NG Tankless Water Heater at Amazon.com. Articles in this section. The Eccotemp i12-NG is a Natural Gas-powered, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. Thank you in advance! The Eccotemp i12-LP is … E1 appears especially when the gas pressure is not enough to feed the unit. Covers models i12-LP and i12-NG. Hello again! On the right side of the water heater, there is a plate that specifies LP for Liquid Propane or NG for Natural Gas. This model features a sleek black gorilla glass casing, fully automatic temperature controls for prescision, touch screen and LCD temperature display which shows output temperature as well as GPM flow. Can you please help me? Next, verify that your gas supply is turned on. Also, it is only activated as needed while being rated at … If the gas company has checked the pressure feed already and is in the right column (8-11 inches of water column) then we have to check the screen filter if it is clogged. If you are getting an E1 error code, first verify that your water heater is the correct gas type. The gas valve is not opened or fully opened. © 2016 Audrey Gadzekpo. Select Page. 1-866-356-1992 Does the E1 exhibit after 2 burners fire up or just one? SERIAL #: TYPE GAS: Minimum Inlet Gas Pressure: Minimum Input Rating (Btu per hour): Maximum Input Rating (Btu per hour): Volta. The E1/E2 error code is caused by the flame circuit not detecting flame at the burner. In a proper ignition sequence, the fan will come on, the display will show ground water temperature, and you will hear a series of fast, high pitched clicking followed by a few lower pitched clicks which are noticeably slower. Find helpful customer reviews and review ratings for Eccotemp 40HI-NG 6.3 GPM Indoor Natural Gas Whole House Indoor Tankless Water Heater at Amazon.com. The gas pressure of Liquid Propane should be 8-11 inches of water column and the gas pressure of Natural Gas should be 4-6 inches of water column. Summerville, SC 29483 United States. View online or download Eccotemp iE-27 Quick Start Manual About Eccotemp.com Eccotemp Systems, LLC 315-A Industrial Rd. Rated at an impressive 4 GPM, the Eccotemp i12-NG Tankless Water Heater is a natural gas fired, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. The E1 code indeed pertains to Gas. The Eccotemp i12-LP is … Eccotemp i12-LP. We regret any inconvenience that this issue may be causing you and please be assured that we will do what is necessary to resolve it. he Eccotemp i12-LP has a new revolutionary design, making it unlike any other tankless water heater on the market today. If you are getting an E1 error code, first verify that your water heater is the correct gas type. Rated at an impressive 3 GPM, the Eccotemp i12-LP Tankless Water Heater is a liquid propane fired, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. Thank you for all of your help! Read … If this matches, verify that your installer checked to make sure that … We will do everything we can to get you some hot water running smoothly as quick as possible. Please don't hesitate to contact us anytime or to update this ticket as needed. It should go through this sequence twice if it does not ignite. Let us know if you need us in the future. Eccotemp iE-27 Pdf User Manuals. First, look for the information plate on the side of the water heater and confirm that your gas supply (Natural Gas or Liquid Propane) matches what is designated for the water heater. FVI-12 LP/NG Whole Home Tankless Water Heater, Manual del calentador de agua sin tanque para toda la casa Eccotemp FVI-12 LP / NG * español, Eccotemp FVI-12 LP/NG Whole Home Tankless Water Heater Manual *English, E3 Error Code on my Whole Home Unit: FVI12-LP/NG, Ticket Example: FVI12-LP/NG Water Pressure Adjustment, Ticket Example: FVI-12 Intermittent Temperature Reading, Ticket Example: FVI-12 shuts down when I mix hot and cold. [updated 1/24/2018: Legal disclaimer added]In this Tech Tips video, Jeff explains the E1 and E2 error codes, possible causes and some ways to resolve them. 45 Series (45H/45HI) Whole Home Tankless Water Heater, Manuel du chauffe-eau pour toute la maison Eccotemp 45H / HI LP / NG * Français, Manual del calentador de agua sin tanque para toda la casa Eccotemp 45H / HI LP / NG * Español, Eccotemp 45H/HI LP/NG Whole Home Tankless Water Heater Manual *English, How to Replace the Flame Sensor on the 45 Series, How To Replace the Over Temperature Sensor on the 45 Series, Gas Piping Facts: Information for properly sizing gas lines for use with tankless water heaters, Gas Pipe Sizing and how it affects the functionality of your 45, Ticket Example: My 45H-NG/LP unit will not ignite. While the Eccotemp is gas powered, it requires no pilot light to worry about. This will help us narrow down what it could be. If you do need us again in the future, you can either respond to this very same ticket in your email and it will open back up, or you can create a new support ticket on our support page at support.eccotemp.com. AUTOMATIC INSTANTANEOUS WATER HEATER. January 9, 2021 The E1 error code is directly related to an issue involving your gas supply. Water shut-off valve is … If I happen to need you again, what do I do? eccotemp e3 error code . Sometimes is something as simple as a screen filter. We are so glad that helped you. by | Jan 8, 2021 | Uncategorized | 0 comments | Jan 8, 2021 | Uncategorized | 0 comments For your records, your ticket number is located above. If this matches, verify that your installer checked to make sure that the gas is the correct pressure for your 45H/HI. To view an online pdf version of this manual click below: To view this manual in other languages please click here. Thank you for contacting Eccotemp Systems Help Desk. eccotemp error codes. The Eccotemp i12-NG is perfect for … MODEL #: i12. About Eccotemp.com Eccotemp Systems, LLC 315-A Industrial Rd. I decided to take your advice and clean the screen filter. 1.Try tapping on the solenoid valve to ensure that it is not stuck. Hi, I need help with my 45 HI NG. Also, make sure your installer used a regulator capable of delivering the proper gas flow needed for the 140,000BTU 45H/HI. We just hooked it up and it keeps giving us an error code of E1. Summerville, SC 29483 United States. Read honest and unbiased product reviews from our users. Rated at an impressive 4 GPM, the Eccotemp i12-NG Tankless Water Heater is a natural gas fired, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. i12 water heater pdf manual download. Have you tried cleaning the screen filter. g. e: 120 Volts. Summerville, SC 29483 United States. We are sorry that you are having issues with your new setup. This model features sleek black tempered glass paneling, fully automatic temperature controls for precision, and a touch screen with an LED temperature display that shows output temperature and GPM flow. Eccotemp EZ-Flush i12 Pdf User Manuals. Rated at an impressive 4 GPM, the Eccotemp i12-LP Tankless Water Heater is a liquid propane fired, indoor model designed for small to medium hot water production where you need more than one hot water application at the same time. This model also offers a 35 to 40-degree Fahrenheit temperature rise when operating at a flow rate of 4 GPM and a 77-degree Fahrenheit temperature rise at 1.5 GPM. About Eccotemp.com Eccotemp Systems, LLC 315-A Industrial Rd. View online or download Eccotemp EZ-Flush i12 Use & Care Manual I’m not a super handy person with this sort of thing. The E1 error code is directly related to an issue involving your gas supply. I looked in the manual, but I don’t quite understand. After I put it back on, the unit fired up with no problem and is running great! This model also offers a 35 to 40-degree Fahrenheit temperature rise when operating at a flow rate of 4 GPM and a 77-degree Fahrenheit temperature rise at 1.5 GPM. Hey Sarah! The Eccotemp i12-LP Water Heater is tankless, as well as powered by gas, so it reduces the consumption of energy. View and Download Eccotemp I12 use & care manual online. Lastly, after doing all of this, make sure that you are not out of gas. An incorrect gas pairing can result in incomplete ignition or it can cause the water heater to burn incorrectly.
Home Place Jarrell, Tx,
34 Chevy Sedan Delivery,
Why Won't Certain Websites Load,
Answers To Delta Math Problems,
Spider Farmer 4000 Uk,
Gene Deckerhoff Net Worth,
American Journey Vs Blue Buffalo,
War Thunder Me 262 C1a,
Glock 44 Trijicon Sights,
Overweight And Obesity Management,